DAS Company is an authorized Himel distribution partner, stocking and supplying the complete Himel low-voltage protection portfolio — HDBK and H3 series MCBs (6kA and 10kA), FEN/LES/FEH series moulded-case circuit breakers (35–50kA, electronic LSIG trip), RCCB and RCBO residual current devices, DC circuit breakers for solar PV applications, AC contactors and Himel distribution board enclosures — to electrical contractors, panel builders and solar installers across Europe from our Bulgaria distribution base, at IEC-certified quality and competitive B2B pricing.
Himel is a multinational manufacturer and provider of low-voltage electrical protection, distribution and control products — with a mission to make efficient and reliable power accessible across residential, commercial and industrial applications worldwide. Himel's product range covers MCBs, MCCBs, RCCBs, RCBOs, DC circuit breakers, contactors and distribution enclosures, all manufactured to IEC 60947-2 and IEC 60898-1 standards with CE marking for European installation. Himel products are certified for wide operating temperature ranges (-40°C to +70°C) — exceeding the standard IEC -5°C to +40°C ambient requirement and covering outdoor and cold climate installation applications without derating. Himel's patented arc-quenching chamber design ensures rapid arc extinction in MCCBs and MCBs, contributing to the high breaking capacities achieved at compact frame sizes. The Himel product range offers IEC-certified protection device quality at pricing positioned significantly below European brand equivalents — making Himel a preferred specification for large residential developments, commercial panel builds and solar PV protection applications where circuit protection cost is a primary project variable.
The Himel H3 series MCB (1P, 1P+N, 2P, 3P, 4P, 6A–63A, B and C trip curves) provides 6kA rated breaking capacity to IEC 60898-1 for final circuit protection in residential and commercial distribution boards. The N-pole design provides two options: Type B (N-pole with contacts but no protection, closes earlier and opens later than the 3 phase poles) and Type C (N-pole with contacts and overcurrent protection) — covering both standard and protective-neutral circuit configurations. The HDBK series (compatible with NEMA load centre format) extends Himel MCB availability to NEMA-format panel applications in North American export machine and commercial projects where both IEC and NEMA panel formats are required from a single component supplier. All H3 and HDBK MCBs include auxiliary contact, alarm contact and shunt release accessory options — enabling remote trip indication and automated disconnection from standard MCB bodies without upgrading to MCCB frame sizes. Operating temperature rating of -40°C to +70°C covers Arctic cold store, outdoor metering cabinet and tropical climate installation without derating correction.
The Himel FEN series MCCB (200A, 3P, 35kA Icu) provides microprocessor-based electronic LSIG (Long time, Short time, Instantaneous, Ground fault) trip unit protection for main and sub-distribution panel incoming feeders. The LES series (250A and 400A, 3P, 36kA) extends LSIG electronic protection to higher current mains and bus coupler applications — with adjustable overload (Ir), short-circuit delay (Isd) and instantaneous settings for selective coordination with downstream H3 MCBs and upstream LV distribution transformers. The FEH series (160A, 3P, 50kA) provides the highest breaking capacity in the Himel MCCB range — targeting main incoming protection in high fault-current environments close to large transformer secondaries or short cable LV mains connections in industrial and commercial substation switchboards. All Himel MCCB variants with electronic LSIG trip include Modbus RTU communication capability (optional module) for integration with energy monitoring systems and smart building management platforms without a separate power meter. Multi-selection between electronic and electromagnetic trip type allows the same frame to serve both cost-sensitive and fully-featured protection panel requirements.
Himel RCCB (2P and 4P, 25–125A, 30mA / 100mA / 300mA, Type AC) provides earth leakage protection for final distribution circuits in compliance with IEC 61008-1 — covering residential distribution boards, commercial final circuits and light industrial socket outlet protection. The Himel RCBO combines overcurrent (MCB) and residual current protection in a single DIN-rail device — available in 1P+N configuration (6A–40A, 30mA) for individual circuit protection in consumer units where separate MCB and RCCB combination would exceed available DIN-rail space. The Phase-Neutral MCB with integrated protection option allows simplified wiring in 230V final circuits without requiring a separate neutral RCD monitoring connection. All Himel residual current devices are Type AC (detects sinusoidal AC leakage) — for standard residential and commercial applications where Type A (AC + pulsating DC) is not specifically required by the installation standard.
Himel DC MCBs provide overcurrent and short-circuit protection for DC circuits in solar photovoltaic systems, battery energy storage, electric vehicle charging and DC distribution panels — where standard AC circuit breakers are not suitable due to the sustained DC arc that cannot be extinguished by zero-crossing interruption. Himel DC MCBs are rated for 250V DC to 1000V DC (string protection level) in 1P and 2P configurations — covering both standard 600V DC and high-voltage 1000V DC solar string combiner box applications to IEC 60947-2 DC application requirements. The patented arc quenching design enables reliable interruption of DC fault currents at the rated DC voltage — a critical safety requirement for solar PV string protection where sustained DC arcing can cause combiner box fires if the protective device fails to interrupt at the rated voltage.
Himel AC contactors (9A–630A AC-3 rating) cover direct-on-line, reversing and star-delta motor starting for IEC 60947-4-1 compliant industrial motor starter panels. Available in 24V, 110V and 230V AC coil options with standard 1NO+1NC auxiliary contact blocks as standard across all frame sizes. Himel contactors are a directly specified cross-reference to ABB A-series, Schneider Electric TeSys and Siemens SIRIUS equivalents for cost-reduction panel builds — providing IEC-compliant quality at reduced component cost for panel builders and contractors with price-competitive project requirements. Thermal overload relays for Himel contactor direct-mounting cover 0.1A to 95A motor protection range with trip class TC10 and TC20.
DAS Company provides access to current Himel pricing for authorized B2B buyers across Europe. Himel products deliver IEC-certified protection at pricing typically 30–50% below equivalent European brand components — making Himel the preferred specification for large-volume residential panel builds, solar PV combiner protection and commercial projects where circuit protection budget is a primary constraint. Product categories with available pricing include H3 MCBs (by pole, curve and breaking capacity), FEN/LES/FEH MCCBs (by frame and trip unit), RCCBs and RCBOs, DC MCBs (by voltage and current rating) and AC contactors. Contact our sales team for cross-reference from ABB, Schneider Electric, Siemens or Legrand equivalents and volume project pricing.